Novedades Onset

Revista HOBO News

Tablas Comparativas

Preguntas Frecuentes

Aplicaciones y Soluciones

Laboratorios Onset

Solicitar Información

Solicitar Catálogo General

 

U14-001 

 
Registrador de Datos HOBO® U14 con Display LCD para Temperatura/Humedad Relativa

Accessories for the U14-001

ARA
2-Zone Remote Alarm
AVD-45
Autodialer
U-DT-1
HOBO® U-Shuttle

 Software requerido  HOBOware

ver manual PDF

 

Technical Specifications
Environmental
  • Operating temperature range -20°C to +50°C,  0 to 100% RH non-condensing
  • Operating relative humidity range 0 to 95%, non-condensing, noncorrosive environment

Logger Capabilities

  • Capacity:
    Temp and RH: 21,500 measurements
    Temp Only: 43,000 measurements
  • Software-selectable sampling intervals: 1 second up to 18 hours, recording times up to 1 year
  • Programmable start time/date
  • Recording modes: Stop when full
  • Launch Modes: Immediate, Delayed
  • Nonvolatile EEPROM memory retains data even if batteries fail

LCD

  • Size: 33 x 50.8 mm (1.3 x 2 inches)
  • Displays temperature and relative humidity simultaneously
  • Displays °C or °F (selectable within host software)
  • Displays memory remaining and battery level
  • Displays flashing ALERT for out-of-limits conditions (selectable within host software) and stops flashing on offload or return to normal range.

Alarms

  • High and low set points for both temperature and relative humidity
  • Selectable delays for each set point.
  • Alert conditions reset on offload or return to normal range.
  • Selectable Contact Relay: Normally Closed or Normally Open
  • Contact rating: 48VDC, 1A max
  • Contact resistance: less than 1 Ohm
  • Wire size range is 22AWG to 14AWG
  • 0% Low Battery Range Communications
  • Offloads data to PC or U-Shuttle via USB cable
  • Readout full logger (64K) in less than 30 seconds

Timekeeping

  • Time accuracy: ±1 minute per month at +20°C.

Power

  • 3 AAA Alkaline batteries, user-replaceable

Size/Weight

  • 5.8 x 7.4 x 3.8 cm (2.3 x 2.9 x .85 inches)
  • 46 g (16.0 oz) with batteries

Internal 12-Bit Temperature Sensor

  • Measurement range: -20°C to +50°C
  • Accuracy: 0.2°C over 0° to 50°C
  • Resolution: 0.03% RH @ 25°C
  • Response time: 15 minutes (to 90% in airflow of 1 m/sec)
  • Temperature Accuracy Drift: Negligible

Internal 12-Bit Relative Humidity Sensor

  • User replaceable
  • Measurement range: 0-100% RH, -20 to 50°C
  • Accuracy: +/- 2.5% from 10 to 90% RH.
  • Resolution: 0.03% RH @ 25°C
  • Response time to 90%: 2 minutes (to 90% in airflow of 1 m/sec)
  • Accuracy Drift: <2% over 5 years typical

External Sensors
For External Sensor Specifications, see the sensor’s user manual.


Battery Life
The batteries will last one year in typical conditions (logging intervals of ≥ 1 minute with weekly offloads and average temperatures greater than 10°C or +50°F). Frequent offloads and/or extreme temperatures will reduce battery life.

At temperatures below freezing (0°C or +32°F), batteries will typically require replacement every six months. In these conditions the battery level bar graph should be checked regularly.

U14-002

Registrador de Datos HOBO® U14 con Display LCD para Sensores Externos de Temperatura y/o Temp/HR.

Ver sensores : S-TMB-M00X   y S-THB-MMX

Accessories for the U14-001

ARA
2-Zone Remote Alarm
AVD-45
Autodialer
U-DT-1
HOBO® U-Shuttle
H14-CASE-4X
Protective Case for HOBO LCD with External Input

 Software requerido  HOBOware

ver manual PDF
Technical Specifications
Environmental
  • Operating temperature range -20°C to +50°C, 0 to 100% RH non-condensing
  • Operating relative humidity range 0 to 95%, non-condensing, noncorrosive environment

Logger Capabilities

  • Capacity:
    Temp and RH: 21,500 measurements
    Temp Only: 43,000 measurements
  • Software-selectable sampling intervals: 1 second up to 18 hours, recording times up to 1 year
  • Programmable start time/date
  • Recording modes: Stop when full
  • Launch Modes: Immediate, Delayed
  • Nonvolatile EEPROM memory retains data even if batteries fail

LCD

  • Size: 33 x 50.8 mm (1.3 x 2 inches)
  • Displays temperature and relative humidity simultaneously
  • Displays °C or °F (selectable within host software)
  • Displays memory remaining and battery level
  • Displays flashing ALERT for out-of-limits conditions (selectable within host software) and stops flashing on offload or return to normal range.

Alarms

  • High and low set points for both temperature and relative humidity
  • Selectable delays for each set point.
  • Alert conditions reset on offload or return to normal range.
  • Selectable Contact Relay: Normally Closed or Normally Open
  • Contact rating: 48VDC, 1A max
  • Contact resistance: less than 1 Ohm
  • Wire size range is 22AWG to 14AWG
  • 0% Low Battery Range Communications
  • Offloads data to PC or U-Shuttle via USB cable
  • Readout full logger (64K) in less than 30 seconds

Timekeeping

  • Time accuracy: ±1 minute per month at +20°C.

Power

  • 3 AAA Alkaline batteries, user-replaceable

Size/Weight

  • 5.8 x 7.4 x 3.8 cm (2.3 x 2.9 x .85 inches)
  • 46 g (16.0 oz) with batteries

External Sensors
For External Sensor Specifications, see the sensor’s user manual.


Battery Life
The batteries will last one year in typical conditions (logging intervals of ≥ 1 minute with weekly offloads and average temperatures greater than 10°C or +50°F). Frequent offloads and/or extreme temperatures will reduce battery life.

At temperatures below freezing, batteries will typically require replacement every six months. In these conditions the battery level bar graph should be checked regularly.

 

Equipos  Instrumentación  y  Control  S.L.

Urbanización Prado Norte, c/ Fresno  1 – bis  28110 Algete – MADRID

Telf.: 91 628 0817  Fax: 91 628 0453  Email: info@eiccontrol.com