U14-001

Registrador de Datos HOBO®
U14 con Display LCD para Temperatura/Humedad
Relativa
Accessories for the
U14-001
ARA
2-Zone Remote Alarm |
 |
Software
requerido
HOBOware
|
|
Technical Specifications |
Environmental
- Operating temperature
range -20°C to +50°C, 0 to 100% RH non-condensing
- Operating relative
humidity range 0 to 95%, non-condensing, noncorrosive
environment
Logger Capabilities
- Capacity:
Temp and RH: 21,500 measurements
Temp Only: 43,000 measurements
- Software-selectable
sampling intervals: 1 second up to 18 hours, recording
times up to 1 year
- Programmable start
time/date
- Recording modes: Stop
when full
- Launch Modes: Immediate,
Delayed
- Nonvolatile EEPROM
memory retains data even if batteries fail
LCD
- Size: 33 x 50.8 mm (1.3
x 2 inches)
- Displays temperature
and relative humidity simultaneously
- Displays °C or °F (selectable
within host software)
- Displays memory
remaining and battery level
- Displays flashing ALERT
for out-of-limits conditions (selectable within host
software) and stops flashing on offload or return to
normal range.
Alarms
- High and low set points
for both temperature and relative humidity
- Selectable delays for
each set point.
- Alert conditions reset
on offload or return to normal range.
- Selectable Contact
Relay: Normally Closed or Normally Open
- Contact rating: 48VDC,
1A max
- Contact resistance:
less than 1 Ohm
- Wire size range is
22AWG to 14AWG
- 0% Low Battery Range
Communications
- Offloads data to PC or
U-Shuttle via USB cable
- Readout full logger
(64K) in less than 30 seconds
Timekeeping
- Time accuracy: ±1
minute per month at +20°C.
Power
- 3 AAA Alkaline
batteries, user-replaceable
Size/Weight
- 5.8 x 7.4 x 3.8 cm (2.3
x 2.9 x .85 inches)
- 46 g (16.0 oz) with
batteries
Internal 12-Bit
Temperature Sensor
- Measurement range:
-20°C to +50°C
- Accuracy: 0.2°C over 0°
to 50°C
- Resolution: 0.03% RH @
25°C
- Response time: 15
minutes (to 90% in airflow of 1 m/sec)
- Temperature Accuracy
Drift: Negligible
Internal 12-Bit
Relative Humidity Sensor
- User replaceable
- Measurement range:
0-100% RH, -20 to 50°C
- Accuracy: +/- 2.5% from
10 to 90% RH.
- Resolution: 0.03% RH @
25°C
- Response time to 90%: 2
minutes (to 90% in airflow of 1 m/sec)
- Accuracy Drift: <2%
over 5 years typical
External Sensors
For External Sensor Specifications,
see the sensor’s user manual.
Battery Life
The batteries will last one year in typical conditions (logging
intervals of ≥ 1 minute with weekly offloads and average
temperatures greater than 10°C or +50°F). Frequent offloads
and/or extreme temperatures will reduce battery life.
At temperatures below
freezing (0°C or +32°F), batteries will typically require
replacement every six months. In these conditions the
battery level bar graph should be checked regularly.
|
|
U14-002
Registrador de Datos HOBO®
U14 con Display LCD para Sensores Externos de Temperatura y/o Temp/HR.
Ver sensores :
S-TMB-M00X
y
S-THB-MMX
Accessories
for the U14-001
ARA
2-Zone Remote Alarm |
 |
H14-CASE-4X
Protective Case for HOBO LCD with External Input |
 |
Software requerido
HOBOware
|
Technical Specifications |
Environmental
- Operating temperature range
-20°C to +50°C, 0 to 100% RH non-condensing
- Operating relative humidity
range 0 to 95%, non-condensing, noncorrosive environment
Logger Capabilities
- Capacity:
Temp and RH: 21,500 measurements
Temp Only: 43,000 measurements
- Software-selectable
sampling intervals: 1 second up to 18 hours, recording times
up to 1 year
- Programmable start
time/date
- Recording modes: Stop when
full
- Launch Modes: Immediate,
Delayed
- Nonvolatile EEPROM memory
retains data even if batteries fail
LCD
- Size: 33 x 50.8 mm (1.3 x 2
inches)
- Displays temperature and
relative humidity simultaneously
- Displays °C or °F (selectable
within host software)
- Displays memory remaining
and battery level
- Displays flashing ALERT for
out-of-limits conditions (selectable within host software)
and stops flashing on offload or return to normal range.
Alarms
- High and low set points for
both temperature and relative humidity
- Selectable delays for each
set point.
- Alert conditions reset on
offload or return to normal range.
- Selectable Contact Relay:
Normally Closed or Normally Open
- Contact rating: 48VDC, 1A
max
- Contact resistance: less
than 1 Ohm
- Wire size range is 22AWG to
14AWG
- 0% Low Battery Range
Communications
- Offloads data to PC or U-Shuttle
via USB cable
- Readout full logger (64K)
in less than 30 seconds
Timekeeping
- Time accuracy: ±1 minute
per month at +20°C.
Power
- 3 AAA Alkaline batteries,
user-replaceable
Size/Weight
- 5.8 x 7.4 x 3.8 cm (2.3 x
2.9 x .85 inches)
- 46 g (16.0 oz) with
batteries
External Sensors
For External Sensor Specifications,
see the sensor’s user manual.
Battery Life
The batteries will last one year in typical conditions (logging
intervals of ≥ 1 minute with weekly offloads and average
temperatures greater than 10°C or +50°F). Frequent offloads and/or
extreme temperatures will reduce battery life.
At temperatures below freezing,
batteries will typically require replacement every six months.
In these conditions the battery level bar graph should be
checked regularly. |
|